r Put the bearings into two opposite indents in the case top as shown in Figure K.
r Place the six slide contactors on the selector knobs as shown in Figure K.
r Place the selector knob into the case top so that the springs fit over the ball bearings as shown in Figure K.
r Place the PC board over the selector knob. Be sure that the 8-pin socket slides into its hole. Then fasten the
PC•board with three 6mm screws as shown in Figure K.
r Insert the 0.5A, 250V fuse into the fuse clips. Your fuse may be unmarked.
r Peel the backing off of the front label and place it on the case top.
r Connect a 9V battery to the battery snap.
-7-
Figure K
PC•Board
6mm Screws
Slide Contactor
Rib
Close-up View
Bearings
Battery Compartment
Case Top
Selector Knob